Patch Name: PHKL_1556 Patch Description: Diskless systems get panic "Kernel DMEM protection fault" in KI code. Symptoms: Diskless systems panic with "Kernel DMEM protection fault" message on console. The pcsq.pcoq value in the panic message points to ki_dm1_send+0x90. This can be checked using adb. As an example if the the console message says pcsq.pcoq = 0.10ea2c, entering this command: adb /hp-ux /dev/kmem then typing: 0x10ea2c/i will give: ki_dm1_send+90: stw arg1,0(arg3) KI stands for Kernel Instrumentation. The chances of this problem occuring become more likely as the number of cnodes increases. Fix: The problem was that the KI code was looking at a mbuf after it had been freed. If an interrupt happens and the mbuf gets reallocated between the time the mbuf was freed and when the KI code looks at it, the bus error could occur or at best KI would get the wrong information. The fix was to have KI look at the mbuf before it was freed. Path Name: /hp-ux_patches/s700/8.X/PHKL_1556 Effective Date: 920925 Patch Files: /system/PHKL_1556/new/conf/dm.o SR/APR#: 5003022830 "what" string/timestamp: dm.o: PATCH_8.07: dm.o 1.9.61.2 92/09/25 PHKL_1556 "sum" output: 33531 16 dm.o Dependencies: None. Supersedes: None. Patch Package Size: 41 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHKL_1556). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHKL_1556.updt" (this assumes that you are in the /tmp directory where PHKL_1556.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHKL_1556/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHKL_1556.text file to /system/PHKL_1556 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHKL_1556.updt of=/dev/rmt/0m bs=2048