Patch Name: PHSS_4528 Patch Description: s300_400 9.X SharedX July 94 Periodic Patch New changes: 94/07 - To fix the customize file problem with heterogeneous clusters. (5003195800) Previously released patch changes retained: 94/03 - STARS #5003182469: The X server could be crashed when a shared window was partially offscreen (negative y). 94/03 - This is to correct a defect in the SHAREDX product customize script which allows the following line to stay in the /etc/filesets/SHAREDX file: /usr/lib/X11/extensions/libSXR5.sl+/HP-PA The effect of this is that when the user does "rmfn -l SHAREDX" and the /usr/lib/X11/extensions/libSXR5.sl+/HP-PA line exists, then the SHAREDX decustomize script runs, which moves /usr/lib/X11/extensions/libSXR5.sl.stubs+/HP-PA to /usr/lib/X11/extensions/libSXR5.sl+/HP-PA and when the fileset is de-installed, the newly moved stubs file is removed, and the net effect is that the X server is not able to start. Path Name: /hp-ux_patches/s300_400/9.X/PHSS_4528 Effective Date: 940727 OS Release: 9.00 9.03 Reboot Required: No Patch Files: /usr/lib/X11/extensions/libSXR5.sl /usr/lib/X11/extensions/libSXR5.sl.real /usr/lib/X11/extensions/libSXR5.sl /usr/lib/X11/extensions/libSXR5.sl.real SR#: 5003182469 5003195800 "what" string/timestamp: SX.cust.fix: libSXR5.sl: libSXR5.sl: SharedX Extensions Lib., Version 2.2 A.B9.03' - 9/17/93 (build date: Wed Jun 1 14:28:39 MDT 1994) X Window System, Version 11 HP-UX 9.* Patched R5+ libSXR5.sl.real: libSXR5.sl: SharedX Extensions Lib., Version 2.2 A.B9.03' - 9/17/93 (build date: Wed Jun 1 14:28:39 MDT 1994) X Window System, Version 11 HP-UX 9.* Patched R5+ "sum" output: 3354 5 SX.cust.fix 29696 196 libSXR5.sl 29696 196 libSXR5.sl.real Dependencies: None Supersedes: PHSS_3899 Patch Package Size: 267 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_4528). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_4528.updt" (this assumes that you are in the /tmp directory where PHSS_4528.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_4528/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_4528.text file to /system/PHSS_4528 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_4528.updt of=/dev/rmt/0m bs=2048