Patch Name: PHSS_4477 Patch Description: s300_400 9.X cumulative hpgl2 and CADplt drivers patch set_p1_p2(), the PS parameters are not calculated correctly if p1 and p2 are not both the same sign. i.e. if p1x, and p2x or p1y and p2y are not of the same sign, then the PS values are incorrect if the absolute value of p1 is not the same as p2. problem is in both the hpgl2 and CADplt drivers PHSS_3993: --------- Fixes plot clip (incorrect hard clip limits) problem seen on large format plotters. The fix is for both shared and archive versions of the CADplt2 plotter driver, libddCADplt.sl and libddCADplt.a. This is the s300/400 version of the s700 PHSS_2721 patch, plus an additional clilp limit problem that was found after the s700 patch was created. Path Name: /hp-ux_patches/s300_400/9.X/PHSS_4477 Effective Date: 940706 OS Release: 9.00 9.03 Reboot Required: No Patch Files: /usr/lib/libddCADplt.a /usr/lib/libddCADplt.sl /usr/lib/libddhpgl.a /usr/lib/libddhpgl.sl SR#: 1653095703 "what" string/timestamp: libddCADplt.a: STARBASE HP-UX 9.0 A.09.00 920904 CADplt $Revision: 500.1.1.2 $ STARBASE HP-UX 9.0 A.09.00 920904 CADplt2 $Revision: 500.1.1.4 $ libddCADplt.sl: STARBASE HP-UX 9.0 A.09.00 920904 CADplt $Revision: 500.1.1.2 $ STARBASE HP-UX 9.0 A.09.00 920904 CADplt2 $Revision: 500.1.1.4 $ libddhpgl.a: STARBASE HP-UX 9.0 A.09.00 920904 libddhpgl.a $Revision: 500.1.1.1 $ libddhpgl.sl: STARBASE HP-UX 9.0 A.09.00 920904 libddhpgl.a $Revision: 500.1.1.1 $ "sum" output: 53820 133 libddCADplt.a 7581 161 libddCADplt.sl 44313 30 libddhpgl.a 48114 54 libddhpgl.sl Dependencies: None Supersedes: PHSS_3993 Patch Package Size: 256 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_4477). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_4477.updt" (this assumes that you are in the /tmp directory where PHSS_4477.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_4477/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_4477.text file to /system/PHSS_4477 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_4477.updt of=/dev/rmt/0m bs=2048